HOME >> NEWS
NEWS
  • Overview and installation of pressure control valve

     

    The pressure control valve is a general term for valves that control pressure. In common usage, we refer to all valves that control pressure collectively as pressure control valves. Sometimes, pressure control valves are also referred to simply as Pressure valves are primarily used to meet the force or torque requirements imposed on the actuator. They include safety valves, relief valves, pressure reducing valves, and sequence valves.

  • The installation and commissioning of pneumatic control valves are particularly important

     

    A pneumatic control valve is typically a combination formed after the pneumatic actuator and the control valve are connected, installed, and debugged. Its installation and debugging are extremely important. Here are some details and tips on the installation of pneumatic control valves: 1. During installation, always follow the installation instructions and precautions for pneumatic control valves; 2. Pay attention to the installation environment of the pneumatic control valve, with temperature and humidity strictly controlled; 3. The front and rear positions of the pneumatic control valve should be located in straight pipe sections with a length not less than 10 times the diameter of the pipeline, to avoid the straight pipe section of the control valve being too short and affecting the flow characteristics; 4. Confirm the cleanliness of the pipeline. Foreign objects in the pipeline may damage the sealing surface of the valve or even hinder the movement of the valve core, ball, or butte

  • What is a boiler soot blowing pressure regulating valve?

     

    STY boiler pressure regulating valve for STY boiler:     STY boiler soot blowing pressure regulating valve: It is a high-temperature and high-pressure regulating valve specifically designed for soot blowing systems. The valve is designed in a two-stage sleeve structure. The first-stage sleeve serves as the main regulator of soot blowing pressure, adjusting the pressure and flow rate of the soot blowing gas through the open and closed positions of the valve core. The second-stage sleeve protects the valve core and valve seat, reducing the erosion and abrasion caused by high-speed fluid on the valve core and valve seat.

  • How to solve the leakage problem of electric control valve

     

    During the use of electric control valves, if leakage occurs, it must be addressed promptly. The following methods can be considered:  1) Increase sealing grease: For valves that have not been applied with sealing grease, consider adding sealing grease to enhance the sealing performance of the valve stem. 2) Increasing packing method: To enhance the sealing performance of the packing on the valve stem, the method of increasing packing can be employed. Typically, a double-layer or multi-layer mixed packing form is adopted. Simply increasing the number, such as from 3 to 5 pieces, does not yield significant results.

  • What is a boiler soot blowing pressure regulating valve?

     

    STY boiler pressure regulating valve for STY boiler: The STY boiler soot blowing pressure regulating valve is a high-temperature, high-pressure regulating valve specifically designed for soot blowing systems. This valve features a two-stage sleeve structure. The first-stage sleeve primarily regulates the soot blowing pressure, adjusting the pressure and flow rate of the soot blowing gas through the open and closed positions of the valve core. The second-stage sleeve protects the valve core and seat, reducing the erosion and abrasion caused by high-speed fluid on the valve core and seat.

  • Double-acting pneumatic control valve holding position

     

    In industrial automation control, pneumatic control valves sometimes require fail-safe positioning. Below are two methods for fail-safe positioning of double-acting pneumatic control valves for your reference.     1. This scheme mainly consists of a pneumatic control valve, solenoid valve, positioner, fail-safe valve, check valve, diaphragm pump pressure reducing valve, and air storage tank. Its working principle is as follows: When the control system experiences an air source failure (loss of air), the fail-safe valve (whose action is opposite to that of a fail-safe valve) automatically opens,

  • Selection method of pneumatic control valve in control loop

     

    A pneumatic control valve consists of a pneumatic actuator and a valve. The pneumatic actuator receives an input air signal, generates a corresponding thrust, causes the push rod to displace, and drives the valve to actuate. The valve refers to the valve body assembly connected to the pipeline, which receives the thrust from the actuator's push rod, changes the valve stem displacement, thereby altering the valve opening, and ultimately controlling the change in fluid flow.

  • What is the control method of the pressure control valve?

     

    Pressure control valves come in two types: hydraulic and pneumatic, but their principles are almost the same. Here is an explanation of the hydraulic valve structure: 1 - adjusting screw; 2 - valve body; 3 - pressure regulating spring; 4 - deflection disc; 5 - cone valve; 6 - damping piston. Function: The damping piston serves two functions. Firstly, it provides damping when the cone valve opens or closes, enhancing the pressure regulating stability of the valve. Secondly, it guides the cone valve, improving the sealing performance of the valve.

86-0571-23230855 / 23259188 

13116767583 / 18357012390

HANGZHOU WOYIZIKONG TECHNOLOGY   CO., LTD 

Address: Zhizhongting, Fuchun Street, Fuyang District, Hangzhou City, Zhejiang Province
Service Hotline: 86-0571-23230855 23259188

Mobile phone: 13116767583/18357012390
After sales service: 86-0571-23259188
Email: hzslming@163.com

CALL
Phone
0571-23230855
0571-23259188
13116767583
0571-23259188
Scan with WeChat